{"product_id":"draeger-fabius-gs-anesthesia-machine-with-scio-four-oxi-plus-gas-module-6871801-ri-10-8604700-18-drun-0168","title":"Draeger Fabius GS Anesthesia Machine with Scio Four Oxi Plus Gas Module 6871801 RI 10 8604700-18 DRUN-0168","description":"\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv\u003e\n\u003cp data-path-to-node=\"0\"\u003eThis Draeger Fabius GS (Model 8604700-18 \/ SN: DRUN-0168) is a highly capable and modular anesthesia workstation, specifically configured with advanced gas analysis for superior clinical control. Utilizing the renowned E-vent electrically driven piston ventilator, this system delivers ICU-quality ventilation without the need for drive gas. This makes the Fabius GS an exceptionally efficient choice for low-flow anesthesia, providing precise tidal volumes for both pediatric and adult patients while minimizing hospital gas consumption.\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003eThis particular unit is equipped with the Scio Four Oxi Plus Gas Module, a critical upgrade that enables real-time monitoring Most importantly, the Scio Four module provides automatic identification and quantification of five anesthetic agents, allowing the surgical team to monitor gas concentrations with absolute confidence. Refurbished to factory standards and Biomed-Certified by our expert team in Miami, this workstation offers a streamlined, \"agent-aware\" platform that is both easy to maintain and highly reliable.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eProduct Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003e\u003cb data-path-to-node=\"3,1,0,0\" data-index-in-node=\"0\"\u003eMain Unit\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003e\u003cb data-path-to-node=\"3,1,1,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,2,0\"\u003eDraeger Fabius GS (8604700-18)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003e\u003cb data-path-to-node=\"3,2,1,0\" data-index-in-node=\"0\"\u003eSerial Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,2,0\"\u003eDRUN-0168\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003e\u003cb data-path-to-node=\"3,3,1,0\" data-index-in-node=\"0\"\u003eVentilator\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,2,0\"\u003eE-vent Piston (Volume, Pressure, SIMV\/PS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003e\u003cb data-path-to-node=\"3,4,0,0\" data-index-in-node=\"0\"\u003eGas Module\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003e\u003cb data-path-to-node=\"3,4,1,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,2,0\"\u003eScio Four Oxi Plus (6871801 RI 10)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003e\u003cb data-path-to-node=\"3,6,0,0\" data-index-in-node=\"0\"\u003ePneumatics\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003e\u003cb data-path-to-node=\"3,6,1,0\" data-index-in-node=\"0\"\u003eGas Supply\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,2,0\"\u003e3-Gas (O2, Air, N2O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003e\u003cb data-path-to-node=\"3,7,1,0\" data-index-in-node=\"0\"\u003eSafety\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,2,0\"\u003eS-ORC (Sensitive Oxygen Ratio Controller)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003e\u003cb data-path-to-node=\"3,8,0,0\" data-index-in-node=\"0\"\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003e\u003cb data-path-to-node=\"3,8,1,0\" data-index-in-node=\"0\"\u003eInterface\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,2,0\"\u003eHigh-Contrast Monochrome Screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,0,0\"\u003e\u003cb data-path-to-node=\"3,9,0,0\" data-index-in-node=\"0\"\u003eErgonomics\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,1,0\"\u003e\u003cb data-path-to-node=\"3,9,1,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,2,0\"\u003eStandard Rails for Monitors \u0026amp; Accessories\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,0,0\"\u003e\u003cb data-path-to-node=\"3,10,0,0\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,1,0\"\u003e\u003cb data-path-to-node=\"3,10,1,0\" data-index-in-node=\"0\"\u003eCertification\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,2,0\"\u003eRefurbished \u0026amp; Biomed-Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003e*PULLED FROM WORKING ENVIRONMENT*\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eCONDITION:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eUSED, WORKING -- Unit shows some cosmetic wear but is functional. Sells with the accessories shown in the pictures. This unit will ship via truck using a pallet. May require calibration in order to optimize performance!\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eDisclaimer:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eRegardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.  The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThis unit has been cleaned according to the manufacturer's instructions. Reprocessing\/cleaning will be required before use.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eMedical Equipment Policy:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eWe DO NOT test or certify the equipment being sold for patient use. It is up to the purchaser to meet all requirements and regulatory certification processes deemed necessary per the FDA or any other regulatory agencies that may be applicable. If you purchase medical, laboratory, or any equipment that will be for PATIENT use, it is the BUYER'S responsibility to have the equipment certified, tested, or inspected prior to patient use. No exceptions.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eBy purchasing an item, you agree to the following:\u003c\/b\u003e  We (Seller) do not state or imply the usage of the item being sold. Before using the item individually or on a patient, you (Buyer) will seek, if applicable, the manufacturer or your personal\/medical care\/health care provider for full details on proper usage of the item, instructions for fitting and wearing of an item if applicable, maintenance\/operations, care of item or any regulatory requirements for the item. You (The buyer) of the item agree to use this product at his own risk and agree to hold harmless the seller and release the owner from any damage\/liability he may incur due to the use of the item.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIf you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health:\u003c\/div\u003e\n\u003cdiv\u003eLinks: http:\/\/www.fda.gov\/cdrh\/devadvice\/ or http:\/\/www.fda.gov\/cdrh\/industry\/support\/index.html\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":47649462354150,"sku":"8604700-18-DRUN-0168","price":3500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/9687\/3958\/files\/05-11-26-41.jpg?v=1778522182","url":"https:\/\/loyaltymed.com\/products\/draeger-fabius-gs-anesthesia-machine-with-scio-four-oxi-plus-gas-module-6871801-ri-10-8604700-18-drun-0168","provider":"Loyalty Medical","version":"1.0","type":"link"}