{"product_id":"draeger-fabius-gs-anesthesia-machine-8604700-41-arym-0238","title":"Draeger Fabius GS Anesthesia Machine 8604700-41 ARYM-0238","description":"\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv\u003e\n\u003cp data-path-to-node=\"0\"\u003eThe Draeger Fabius GS (Model 8604700-41 \/ SN: ARYM-0238) is a reliable and highly modular anesthesia workstation designed to grow with your clinical needs. At its core is the high-precision, electrically driven E-vent piston ventilator, which provides ICU-quality performance for pediatric and adult patients. Because the E-vent system does not require drive gas, it is exceptionally efficient for low-flow anesthesia, helping your facility reduce medical gas consumption and lower overall operating costs.\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003eMeticulously refurbished and Biomed-Certified by our expert team in Miami, this unit features a clear, high-contrast monochrome display and a familiar user interface that minimizes the learning curve for staff. The open-architecture design includes standard mounting rails, allowing for the easy integration of patient monitors and data management systems. This Draeger Fabius GS is a proven \"workhorse\" for surgical centers and hospitals looking for a durable, cost-effective anesthesia solution without sacrificing ventilation quality.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eProduct Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003e\u003cb data-path-to-node=\"3,1,0,0\" data-index-in-node=\"0\"\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003eDraeger Medical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003e\u003cb data-path-to-node=\"3,2,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eFabius GS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003e\u003cb data-path-to-node=\"3,3,0,0\" data-index-in-node=\"0\"\u003eRef Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003e8604700-41\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003e\u003cb data-path-to-node=\"3,4,0,0\" data-index-in-node=\"0\"\u003eSerial Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003eARYM-0238\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003e\u003cb data-path-to-node=\"3,5,0,0\" data-index-in-node=\"0\"\u003eVentilator Technology\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003eE-vent Electrically Driven Piston (No drive gas)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003e\u003cb data-path-to-node=\"3,6,0,0\" data-index-in-node=\"0\"\u003eVentilation Modes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003eVolume Control, Pressure Control (Optional), SIMV\/PS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003e\u003cb data-path-to-node=\"3,7,0,0\" data-index-in-node=\"0\"\u003eGas Delivery\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003e3-Gas (O2, Air, N2O) with dual-flow tubes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003e\u003cb data-path-to-node=\"3,8,0,0\" data-index-in-node=\"0\"\u003eVaporizer Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003e2-Position Draeger Interlock (Selectatec compatible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,0,0\"\u003e\u003cb data-path-to-node=\"3,9,0,0\" data-index-in-node=\"0\"\u003eSafety Features\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,9,1,0\"\u003eS-ORC (Sensitive Oxygen Ratio Controller)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,0,0\"\u003e\u003cb data-path-to-node=\"3,10,0,0\" data-index-in-node=\"0\"\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,10,1,0\"\u003eRefurbished \u0026amp; Biomed-Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003e*PULLED FROM WORKING ENVIRONMENT*\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eCONDITION:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eUSED, WORKING -- Unit shows some cosmetic wear but is functional. Sells with the accessories shown in the pictures. This unit will ship via truck using a pallet. May require calibration in order to optimize performance!\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eDisclaimer:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eRegardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.  The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThis unit has been cleaned according to the manufacturer's instructions. Reprocessing\/cleaning will be required before use.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eMedical Equipment Policy:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eWe DO NOT test or certify the equipment being sold for patient use. It is up to the purchaser to meet all requirements and regulatory certification processes deemed necessary per the FDA or any other regulatory agencies that may be applicable. If you purchase medical, laboratory, or any equipment that will be for PATIENT use, it is the BUYER'S responsibility to have the equipment certified, tested, or inspected prior to patient use. No exceptions.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eBy purchasing an item, you agree to the following:\u003c\/b\u003e  We (Seller) do not state or imply the usage of the item being sold. Before using the item individually or on a patient, you (Buyer) will seek, if applicable, the manufacturer or your personal\/medical care\/health care provider for full details on proper usage of the item, instructions for fitting and wearing of an item if applicable, maintenance\/operations, care of item or any regulatory requirements for the item. You (The buyer) of the item agree to use this product at his own risk and agree to hold harmless the seller and release the owner from any damage\/liability he may incur due to the use of the item.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eIf you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health:\u003c\/div\u003e\n\u003cdiv\u003eLinks: http:\/\/www.fda.gov\/cdrh\/devadvice\/ or http:\/\/www.fda.gov\/cdrh\/industry\/support\/index.html\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":47649460420838,"sku":"8604700-41-ARYM-0238","price":2500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/9687\/3958\/files\/05-11-26-37copy.jpg?v=1778521828","url":"https:\/\/loyaltymed.com\/products\/draeger-fabius-gs-anesthesia-machine-8604700-41-arym-0238","provider":"Loyalty Medical","version":"1.0","type":"link"}