{"product_id":"drager-apollo-anesthesia-system-8606500-asnj-0055-04-52-05","title":"Drager Apollo Anesthesia System 8606500 \/ ASJN-0055 - 04.52.05","description":"\u003cdiv class=\"overview__heading\"\u003e\n\u003cp\u003eThe Dräger Apollo Anesthesia System (Model 8606500) is a highly reliable, high-acuity anesthesia workstation engineered to deliver precise ventilation therapy and streamlined clinical workflows. Manufactured in 2016 and equipped with Software Version 04.52.05, this workstation features Dräger’s signature E-Vent® plus electrically driven piston ventilator, which eliminates the need for drive gas and provides ICU-quality respiratory support. Capable of catering to a complete patient spectrum, from neonatal and pediatric to adult patients, it excels at maintaining tight control over low-flow fresh gas delivery while shielding patient lungs through advanced protective ventilation capabilities.\u003c\/p\u003e\n\u003cp\u003eDesigned to enhance surgical team productivity and ensure patient safety, the Apollo features an intuitive visual interface that displays real-time graphical waveforms, loops, and digital fresh gas readouts at a single glance. Its physical chassis offers an ergonomic, well-lit workspace with ample drawer storage, integrated cable management, and a robust mobile base equipped with a central braking mechanism for easy positioning within the OR suite. Thoroughly inspected, calibrated, and biomed-certified to original manufacturer performance standards, this 2016 Dräger Apollo system provides a cost-effective, clinically proven solution for any operating facility.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eProduct Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature \/ Attribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDräger Medical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApollo Anesthesia Workstation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eModel \/ Catalog Part #\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8606500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSerial Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0055\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eYear of Manufacture (DOM)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2016\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSoftware Version\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSW 04.52.05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ePatient Demographics\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdult, Pediatric, Neonatal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eVentilator Technology\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE-Vent® plus (Electronically driven piston ventilator)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eVentilation Modes\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVolume Control (VCV), Pressure Control (PCV), Synchronized Intermittent Mandatory Ventilation (SIMV), Pressure Support (PS), Manual\/Spontaneous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eTidal Volume Range\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 mL – 1400 mL (VCV) \/ 5 mL – 1400 mL (PCV\/PS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eFresh Gas Delivery\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic digital flow measurement and control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDrive Gas Required\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eDisplay\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-resolution color screen with customizable real-time waveforms \u0026amp; loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eSelf-Test Capability\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully automated pre-use system check\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eBattery Backup\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated internal backup battery (minimum 30–90 mins depending on configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eCondition\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefurbished\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*PULLED FROM WORKING ENVIRONMENT*\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDisclaimer: Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.  The purchaser, by bidding on this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit has been cleaned according to the manufacturer's instructions. Reprocessing\/cleaning will be required before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMedical Equipment Policy:\u003c\/strong\u003e We DO NOT test or certify the equipment being sold for patient use. It is up to the purchaser to meet all requirements and regulatory certification processes deemed necessary per the FDA or any other regulatory agencies that may be applicable. If you purchase medical, laboratory, or any equipment that will be for PATIENT use, it is the BUYER'S responsibility to have the equipment certified, tested, or inspected prior to patient use. No exceptions.\u003c\/p\u003e\n\u003cp\u003eBy purchasing an item, you agree to the following:  We (Seller) do not state or imply the usage of the item being sold. Before using the item individually or on a patient, you (Buyer) will seek, if applicable, the manufacturer or your personal\/medical care\/health care provider for full details on proper usage of the item, instructions for fitting and wearing of an item if applicable, maintenance\/operations, care of item or any regulatory requirements for the item. You (The buyer) of the item agree to use this product at his own risk and agree to hold harmless the seller and release the owner from any damage\/liability he may incur due to the use of the item.\u003c\/p\u003e\n\u003cp\u003eIf you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health:\u003cbr\u003eLinks: http:\/\/www.fda.gov\/cdrh\/devadvice\/ or http:\/\/www.fda.gov\/cdrh\/industry\/support\/index.html\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!----\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":48106516119782,"sku":"8606500-ASJN-0055","price":3499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/9687\/3958\/files\/drager-apollo-anesthesia-machine-loyalty-medical-8606500-ASJN-0055-18.jpg?v=1785776099","url":"https:\/\/loyaltymed.com\/es\/products\/drager-apollo-anesthesia-system-8606500-asnj-0055-04-52-05","provider":"Loyalty Medical","version":"1.0","type":"link"}